-40%
Portable Medical Patient Monitor Vital Signs 12 inch ICU + Printer, OPTIONAL CO2
$ 342.67
- Description
- Size Guide
Description
PM10CONTEC CMS8000 Vital Signs 6-parameter patient monitor+printer
Description
Introduction
The monitor has abundant functions that can be used for clinical monitoring with adult, pediatric and neonate. Users may select different parameter configuration according to different requirements. The monitor, power supplied by 100-240V
~
,50/60Hz, adopts 12.1'' color TFT LCD displaying real-time date and waveform. It can synchronously display eight-channel waveform and full monitoring parameters equipped with an optional 48mm thermal recorder. The monitor can be connected to the central monitoring system via wire or wireless network to form a network monitoring system.
This device can monitor such parameters as ECG, RESP, NIBP, SpO2, and dual-channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving.
Features
1)12.1'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech).
2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
3)All-round monitor for adult, pediatric and neonate.
4)With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.
5)Finish all operations by keys and knobs.
6)Maximum 8-channel waveform synchronous display.
7)Display 7-lead ECG waveform on one screen, cascade ECG waveform display
8)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
9)Heart rate variability (HRV) analysis function
10)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
11)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
12)Drug concentration calculation and titration table functions.
13)One-touch printing of trend graph
14)Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.
15)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
16)Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary).
Performance
▲ECG
Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, aVR, aVL, aVF, V
Waveform: 5-lead, dual-channel
3-lead, single-channel
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR:
Measurement and alarm range: 15
~
350 bpm
Accuracy: ±1 % or ±1 bpm, whichever is greater
Alarm accuracy: ± 2 bpm
Resolution: 1 bpm
ST-segment monitoring:
Measurement and alarm range: -2.0 mV
~
+2.0 mV
Accuracy: -0.8 mV
~
+0.8 mV ±0.04 mV or ±10%, whichever is greater
Other range: unspecified
Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,
PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Pacemaker: yes
▲RESP
Method: R-F(RA-LL) Impedance
Respiration rate:
Measurement and alarm range: 0
~
150 rpm
Resolution: 1 rpm
Measurement accuracy: ±2 rpm
Alarm accuracy: ±3 rpm
Apnea alarm: 10
~
40s
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
▲NIBP
Method: Oscillometry
Mode: Manual/AUTO/STAT
Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes
Measurement period in STAT mode: 5 minutes
Measurement and alarm range: 10
~
270 mmHg
Resolution: 1 mmHg
Cuff pressure accuracy: ±3 mmHg
Measurement accuracy:
Maximal mean deviation: ±5 mmHg
Maximal standard deviation: 8 mmHg
Over-pressure protection:
Adult mode: 297±3 mmHg
Pediatric mode: 240±3 mmHg
Neonatal mode: 147±3 mmHg
▲SpO2
Measurement and alarm range: 0
~
100%
Resolution: 1%
Measurement accuracy: 70%
~
100%: ±2%;
0%
~
69%: unspecified
▲PR
Measurement and alarm range: 30
~
250 bpm
Measurement accuracy: ±2 bpm or ±2%, whichever is greater
▲TEMP
Channel: dual-channel
Measurement and alarm range: 0
~
50℃
Resolution: 0.1 ℃
Accuracy: ±0.1 ℃
▲EtCO2 optional
Method: Sidestream or Mainstream
Measuring Range: 0
~
150mmHg
Resolution:
0
~
69 mmHg, 0.1 mmHg
70
~
150 mmHg, 0.25 mmHg
Accuracy:
0
~
40 mm Hg ±2 mm Hg
41
~
70 mm Hg ±5%
71
~
100 mm Hg ±8%
101
~
150 mm Hg ±10%
AwRR Range: 2
~
150 rpm
AwRR Accuracy: ±1BPM
Apnea Alarm: Yes
▲IBP optional
Channel: dual-channel
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and Alarm Range: -10
~
300 mmHg
Resolution 1 mmHg
Accuracy: ±2% or 1mmHg, whichever is greater
▲Power supply: 100-240V
~
, 50/60Hz
▲Safety classification: Class I, type CF defibrillation-proof applied part
Accessories
1)Adult fingertip SpO2 probe (5-pin)
2)Adult NIBP cuff
3)NIBP extension tube
4)ECG lead cable
5)ECG electrode
6)Temperature probe
7)Power cord
8)User Manual
Physical characteristic
Dimension: 314 mm(L) × 145 mm(W) × 264 mm(H)
Weight: 3.9 Kg
Shipping
1. For your earlier and safer to receive the item, please leave us your detail address and telephone number.
2. Your item will be sent via Air mail within 48 hours after payment is received.
3. As the usual way, buyer is responsible for the duties, taxes or other VAT or extra charges from the import countries.
4.All items will be shipped to buyer's PayPal address. Please confirm your PayPal address is correct before purchase.
International Buyers - Please Note:
? Import duties, taxes are not included in item price or shipping charges. These charges are buyer's responsibility.
? Please check with your country's customs office to determine what these additional cost will be prior to bidding
Terms of Sale
Buy Safe Product!
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K Approved
Feedback
Please leave me a positive feedback if you are satisfied with our products, Your positive feedback will be appreciated,thank you.
If you have any problems, please contact us asap before you open a case and leave a negative feedback or ship the item back,
we promise we will give you a satisfied answer, thank you for your understanding!
Return - After service
We offer 60 days return policy. 100% satisfaction is our goal!
1.All items are brand new ,with 1 years warranty.
2.If you have a defective item, you want to return or discount. Please contact us within 2 days from you receive the item.
3.We will refund the money to you when we get the return items or replace item for you.
4. All return items must be returned with its original package and accessories. Customer is responsible for shipping charges on returned items.
About Us
Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.
At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.Most of the domestic hospitals are our customers.Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products.We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you.
Contact Us
Contact Person:Vivian Zhang
Mobile/ICQ/WhatsApp:+8618617816016
Contec Medical Systems Co.,Ltd
Address(US):1440 Chase Avenue,Elk Grove Village,Illinois 60007 United States
Only English User Manual,Please contact us if you need other language manual.