-40%

Pro 12 Inch Patient Monitor 6-parameter ECG SpO2 ICU CCU Vital Signs Monitor FDA

$ 237.07

Availability: 100 in stock
  • All returns accepted: Returns Accepted
  • Brand: Unbranded
  • Features1: Audible & visual alarm available, adjustable
  • Monitor Parameters: Heart Rate
  • Features: portable, convenient for use
  • Optional:: Printer ETCO2 (side stream)
  • Return shipping will be paid by: Buyer
  • Multi-language: English, Spanish, Turkish.
  • Restocking Fee: No
  • Warranty: 2 years
  • Screen Dimensions: 12" TFT display
  • CE FDA: passed
  • UPC: 190891820013
  • MPN: Does Not Apply
  • Condition: New
  • Item must be returned within: 30 Days
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Suitable for: adult, pediatrics and neonate patients

    Description

    Tips:
    12.1-inch Display 6-Parameter Patient Monitor ----ECG, NIBP, SPO2, TEMP, RESP, PR
    Model: RPM-9000A
    Features
    Ergonomic design, portable, convenient for use
    12" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
    Unique digital SPO2 technology can work accurate during motion and low perfusion
    Anti AC & high-frequency electrosurgical & defibrillator’s interference
    Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
    Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
    ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
    Audible & visual alarm available, adjustable
    Patient information management function
    Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
    Optional software upgrading based on USB
    Wired/wireless networking with central monitoring system, up to 64 beds in one group
    Built-in 3 trace thermal recorder for printing real-time and historical data
    Multi-language i.e. English, Spanish, Turkish.
    Super long life rechargeable Lithium battery upto 4 hours of working time
    Suitable for adult, pediatrics and neonate patients
    Standard configuration
    ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery
    Optional
    Dual TEMP
    Dual IBP
    ETCO2 (side stream)
    Thermal recorder
    Wall mount
    Trolley
    Specification
    ECG
    Full lead: I, II, III, AVL, AVR, AVF and V
    Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
    Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
    Band width: 0.05Hz-100Hz(3dB)
    Heart rate
    Scope: 15 times/minute to 300 times/minutes
    Accuracy:  ±1 time/minute
    Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
    Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
    Accuracy: Error rate < 20%
    Undetected rate < 20%
    ST section
    Scope:     ±0.8mV
    Precision :  < ±0.05mV
    SpO2
    Detection scope:   0%-100%
    Accuracy         ±1%     90%-100%
    ±2%      70%-89%
    NIBP
    Theory Electric oscillator
    Cuff gassing time   less than 15 seconds
    First-time gassing : dynamic state 24kPa(180 mmHg)
    Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
    18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
    Automatic detection period: 1 minute to 240 minutes
    Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
    in -90min) and 30min(90 min -240min)
    Detection scope:
    Systolic blood presure:   4kPa -34kPa(30mmHg -255mmHg)
    Diastolic presure             2kPa -29.3kPa(15mmHg -220mmHg)
    Mean presure               2.7kPa~31.3kPa       (20mmHg~235mmHg)
    Detection accuracy
    Static presure: ±3mmHg
    Pulse rate:  ±2%
    Resp
    Chest impedance method or concentration of carbon dioxide at end of respiration
    Scope of chest impedance method     0 time/minute – 100 minutes/minute
    Precision of chest impedance method  time/minute
    Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
    Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
    Detection precision of respiration rate: ±1 time/minute
    Temp
    Single/double path
    Type:    Vascular/surface temperature
    Scope:    20℃~50℃
    Accuracy:  ±0.2℃
    FDA Disclaimer:
    Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.(Seller name:May  City:Beijing  State:Beijing  Country:China  Phone
    :+86 18108119506)
    This item has been cleaned and treated according to the manufacturer's instructions.
    The Fingertip Pulse Oximeter is certified with the US FDA 510K No. K070371, the CE & TUV of Eureope and it is on the Australian Register of Therapeutic Goods (ARTG) with the code 136606.
    The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989
    The Powered Surgical Instrument / Hair Remove Device is certified with the US FDA 510(k) Number:K180353
    The Powered Surgical Instrument / Hair Remove System is certified with the US FDA 510(k) Number:K141973
    massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA 510(k) Number:K161892